Intraocular Lenses

HYDROPHOBIC IOLS
 

Type 63A

Total Diameter

13.0 mm
(over 23.5 D. = 12.5 mm)

Optic Diameter

6.0 mm
PositionCapsular Bag
HapticJ-Loop | 0°
Standard-Diopter-Range 

16.5 – 23.0 D. (0.5 inc.)

On-Request-Range*

10.0 – 16.0 D. (0.5 inc.)

23.5 – 35.0 D. (0.5 inc.)

Theoretical Standard Power

22.0 D.

Theoretical A-Con. (optical)

119.7

Theoretical ACD (optical)

5.96 mm

Haigis

a0=1.30 | a1 = 0.40 | a2 = 0.10

SRK/T | SRKII

118.8 | 119.2

Material

Hydrophobic Acrylic

Water Content

< 0.5 %

Filter

UV-Filter

Refractive Index

1.51

Features

Bend at the optic-haptic juncture will direct the IOL into the posterior direction in the case of capsular contraction.

Rounded profiles at the haptic ends reduce the sticking together of the haptics and optics.

 

Type 63A PRELOADED

Total Diameter

13.0 mm
(over 23.5 D. = 12.5 mm)

Optic Diameter

6.0 mm
PositionCapsular Bag
HapticJ-Loop | 0°
Standard-Diopter-Range 

16.5 – 23.0 D. (0.5 inc.)

Theoretical Standard Power

22.0 D.

Theoretical A-Con. (optical)

119.7

Theoretical ACD (optical)

5.96 mm

Haigis

a0=1.30 | a1 = 0.40 | a2 = 0.10

SRK/T | SRKII

118.8 | 119.2

Material

Hydrophobic Acrylic

Water Content

< 0.5 %

Filter

UV-Filter

Refractive Index

1.51

Incision> 2.8 mm
Features

Bend at the optic-haptic juncture will direct the IOL into the posterior direction in the case of capsular contraction.

Rounded profiles at the haptic ends reduce the sticking together of the haptics and optics.

MediaSurgery Video
Handling Video EYEJET IOL LOTUS

* Other D. on request

HYDROPHILIC IOLS
 

Type 92S

Total Diameter

15.0 mm

Optic Diameter

6.0 mm
Position

Capsular Bag/Sulcus

Haptic

C-Loop | 10°

Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

8.5 – 9.5 D. (0.5 inc.)

30.5 – 40.0 D. (0.5 inc.)

Theoretical Standard Power

23.0 D.

Theoretical A-Con. (optical)

119.7 | Scleral sutured = 120.6

Theoretical ACD (optical)

5.96 | Scleral sutured = 6.48

Haigis

a0=1.40 | a1 = 0.40 | a2 = 0.10

SRK/T | SRKII

119.1 | 119.6

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

MICS (recommendation)

Medicel VISCOJECTTM-BIO 1.8

up to 30.0 D.

MediaSurgery Video
 

Type 92G

Total Diameter

15.0 mm

Optic Diameter

6.5 mm
Position

Capsular Bag/Sulcus

Haptic

C-Loop | 10°

Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

8.5 – 9.5 D. (0.5 inc.)

Theoretical Standard Power

22.0 D.

Theoretical A-Con. (optical)

119.7 | Scleral sutured = 120.6

Theoretical ACD (optical)

5.96 | Scleral sutured = 6.48

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

 

Type 92B

Total Diameter

15.0 mm

Optic Diameter

7.0 mm
Position

Capsular Bag/Sulcus

Haptic

C-Loop | 10°

Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

8.5 – 9.5 D. (0.5 inc.)

Theoretical Standard Power

21.0 D.

Theoretical A-Con. (optical)

119.7 | Scleral sutured = 120.6

Theoretical ACD (optical)

5.96 | Scleral sutured = 6.48

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Note

Cannot be implanted with an

injector due to its optic size

 

Type 92C

Total Diameter

10.5 mm

Optic Diameter

6.0 mm
Position

Capsular Bag

Haptic

4-Loop | 10°

Standard-Diopter-Range 

15.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

8.5 – 14.5 D. (0.5 inc.)

30.5 – 35.0 D. (0.5 inc.)

Theoretical Standard Power

22.0 D.

Theoretical A-Con. (optical)

119.1

Theoretical ACD (optical)

5.61 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

MICS (recommendation)

Medicel VISCOJECTTM-BIO 1.8
up to 30.0 D.

 

Type 97B

Total Diameter

11.0 mm

10.75 mm10.5 mm

Optic Diameter

6.5 mm6.25 mm / 5.75 mm6.0 mm / 5.5 mm
Opticconvexo-concavebiconvexbiconvex
Position

Capsular Bag

Capsular BagCapsular Bag
Haptic

4-Loop | 0°

4-Loop | 0°4-Loop | 0°
Diopter-Range 

-5.0  –  4.5 D.

(0.5 inc.)

5.0  –  14.5 D.

(0.5 inc.)

15.0  –  35.0 D.

(0.5 inc.)

Theoretical Standard Power

22.0 D.

22.0 D.22.0 D.
Theoretical A-Con. (optical)

118.8

118.8118.8
Theoretical ACD (optical)

5.43 mm

5.43 mm5.43 mm
Material

Hydrophilic Acrylic

Hydrophilic AcrylicHydrophilic Acrylic
Water Content

28.0 %

28.0 %28.0 %
Filter

UV-Filter

UV-FilterUV-Filter
Refractive Index

1.46

1.461.46

Recommended Injektor

Medicel ACCUJECTTM 1.8-1P for 1-piece lenses,
inc. size sub 2.2 mm (up to 30 diopters)



 

Type 89A

Indication

Adults/Pediatrics

Total Diameter

7.5 mm
Optic Diamter5.0 mm
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

8.5 – 9.5 D. (0.5 inc.)

30.5 – 35.0 D. (0.5 inc.)

Theoretical Standard Power

23.0 D.

Theoretical A-Con. (optical)

118.2

Theoretical ACD (optical)

5.08 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Injector (recommendation)

Up to +23.0 diopters 
Medicel ACCUJECTTM 2.2-BL (LP604535)
Wound assisted injection: 1.9 – 2.2 mm 
Wound injection: 2.2 mm

  

For all diopters 
Medicel ACCUJECTTM 2.6-BL (LP604505)
Wound assisted injection: 2.2 mm 
Wound injection: 2.6 mm 

Recommended

Caliper Ring*3 for ACCC*2

Type 5
Type 4L (PED)

Feature

No PCO in visual field!

Note

Surgeons must partake in prerequiste course before implantation!
More information

Security AdviceDue to the possibility of Iris capture it is recommended to keep the Iris in miosis for three days!
MediaInfo Bag-In-The-Lens
Surgery Videos
 

Type 89A TORIC

Indication

Adults/Pediatrics

Total Diameter

7.5 mm
Optic Diamter5.0 mm
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

8.5 – 9.5 D. (0.5 inc.)

Theoretical Standard Power

23.0 D.

Cylindrical Power

0.5 – 8.0 D. (0.5 inc.)

Theoretical A-Con. (optical)

118.2

Theoretical ACD (optical)

5.08 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Injector (recommendation)

Up to +23.0 diopters 
Medicel ACCUJECTTM 2.2-BL (LP604535)
Wound assisted injection: 1.9 – 2.2 mm 
Wound injection: 2.2 mm

  

For all diopters 
Medicel ACCUJECTTM 2.6-BL (LP604505)
Wound assisted injection: 2.2 mm 
Wound injection: 2.6 mm 

Recommended

Caliper Ring*3 for ACCC*2

Type 5
Type 4L (PED)

Feature

No PCO in visual field!

Note

Surgeons must partake in prerequiste course before implantation!
More information

Security AdviceDue to the possibility of Iris capture it is recommended to keep the Iris in miosis for three days!
MediaInfo Bag-In-The-Lens
Surgery Videos
Toric Order Form
 

Type 89D

Indication

For small eyes (< 18.0 mm) and/or
small white to white < 10.0 mm.

Total Diameter

6.5 mm
Optic Diamter4.5 mm
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

8.5 – 9.5 D. (0.5 inc.)

30.5 – 35.0 D. (0.5 inc.)

Theoretical Standard Power

23.0 D.

Theoretical A-Con. (optical)

118.2

Theoretical ACD (optical)

5.08 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Injector (recommendation)

Up to +23.0 diopters 
Medicel ACCUJECTTM 2.2-BL (LP604535)
Wound assisted injection: 1.9 – 2.2 mm 
Wound injection: 2.2 mm

  

For all diopters 
Medicel ACCUJECTTM 2.6-BL (LP604505)
Wound assisted injection: 2.2 mm 
Wound injection: 2.6 mm 

Recommended

Caliper Ring*3 for ACCC*2

Type 4L

Feature

No PCO in visual field!

Note

Surgeons must partake in prerequiste course before implantation!
More information

Security AdviceDue to the possibility of Iris capture it is recommended to keep the Iris in miosis for three days!
MediaInfo Bag-In-The-Lens
Surgery Videos
 

Type 89F

Indication

Combined cataract and vitrectomy procedures or in eyes with large pupils.

Total Diameter

8.5/7.5 mm
Optic Diamter5.0 mm
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

8.5 – 9.5 D. (0.5 inc.)

Theoretical Standard Power

23.0 D.

Theoretical A-Con. (optical)

118.2

Theoretical ACD (optical)

5.08 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Injector (recommendation)

Up to +23.0 diopters 
Medicel ACCUJECTTM 2.2-BL (LP604535)
Wound assisted injection: 1.9 – 2.2 mm 
Wound injection: 2.2 mm

  

For all diopters 
Medicel ACCUJECTTM 2.6-BL (LP604505)
Wound assisted injection: 2.2 mm 
Wound injection: 2.6 mm 

Recommended

Caliper Ring*3 for ACCC*2

Type 5

Feature

No PCO in visual field!

Note

Surgeons must partake in prerequiste course before implantation!
More information

Security AdviceDue to the possibility of Iris capture it is recommended to keep the Iris in miosis for three days!
MediaInfo Bag-In-The-Lens
Surgery Videos

* Other D. on request 
*2 Anterior Continuous Curvolinear Capsulorhexis 
*3 Gauge for Capsulorhexis

PMMA IOLS
 

Type 27C

Total Diameter

13.0 mm

Optic Diameter

5.0 mm
PositionCapsular Bag
HapticC-Loop | 6°
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

5.0 – 9.5 D. (0.5 inc.)

30.5 – 51.0 D. (0.5 inc.)

Theoretical Standard Power

22.0 D .

Theoretical A-Con. (optical)

118.7

Theoretical ACD (optical)

5.37 mm

Material

PMMA

Filter

UV-Filter

Refractive Index

1.49

Incision

> 5.0 mm

 

Type 7D

Total Diameter

12.0 mm

Optic Diameter

5.5 mm
PositionCapsular Bag
HapticC-Loop | 5°
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

5.0 – 9.5 D. (0.5 inc.)

30.5 – 73.0 D. (0.5 inc.)

Theoretical Standard Power

22.0 D .

Theoretical A-Con. (optical)

119.3

Theoretical ACD (optical)

5.72 mm

Material

PMMA

Filter

UV-Filter

Refractive Index

1.49

Incision

> 5.5 mm

 

Type 65C

Total Diameter

13.0 mm

Optic Diameter

6.0 mm
PositionCapsular Bag
HapticC-Loop | 5°
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

5.0 – 9.5 D. (0.5 inc.)

30.5 – 40.0 D. (0.5 inc.)

Theoretical Standard Power

22.0 D.

Theoretical A-Con. (optical)

118.7

Theoretical ACD (optical)

5.37 mm

Material

PMMA

Filter

UV-Filter

Refractive Index

1.49

Incision

> 6.0 mm

 

Type 25

Total Diameter

13.5 mm

Optic Diameter

6.0 mm
PositionCapsular Bag
HapticC-Loop | 10°
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

5.0 – 9.5 D. (0.5 inc.)

30.5 – 40.0 D. (0.5 inc.)

Theoretical Standard Power

22.0 D.

Theoretical A-Con. (optical)

118.7

Theoretical ACD (optical)

5.37 mm

Material

PMMA

Filter

UV-Filter

Refractive Index

1.49

Incision

> 6.0 mm

 

Type 62D

Total Diameter

12.0 mm

Optic Diameter

6.5 mm
PositionCapsular Bag
HapticC-Loop | 10°
Standard-Diopter-Range 

10.0 – 27.5 D. (0.5 inc.)

On-Request-Range*

0.0 – 9.5 D. (0.5 inc.)

Theoretical Standard Power

24.0 D.

Theoretical A-Con. (optical)

120.6

Theoretical ACD (optical)

6.48 mm

Material

PMMA

Filter

UV-Filter

Refractive Index

1.49

Incision

> 6.5 mm

 

Type 65D

Total Diameter

13.0 mm

Optic Diameter

6.5 mm
PositionCapsular Bag
HapticC-Loop | 5°
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

5.0 – 9.5 D. (0.5 inc.)

30.5 – 35.0 D. (0.5 inc.)

Theoretical Standard Power

22.0 D.

Theoretical A-Con. (optical)

118.7

Theoretical ACD (optical)

5.37 mm

Material

PMMA

Filter

UV-Filter

Refractive Index

1.49

Incision

> 6.5 mm

 

Type 65E

Total Diameter

13.0 mm

Optic Diameter

7.0 mm
PositionCapsular Bag
HapticC-Loop | 5°
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

5.0 – 9.5 D. (0.5 inc.)

30.5 – 35.0 D. (0.5 inc.)

Theoretical Standard Power

22.0 D.

Theoretical A-Con. (optical)

118.7

Theoretical ACD (optical)

5.37 mm

Material

PMMA

Filter

UV-Filter

Refractive Index

1.49

Incision

> 7.0 mm

 

Type 81F

Total Diameter

13.0 mm

Optic Diameter

7.0 mm
PositionCapsular Bag
HapticC-Loop | 10°
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

5.0 – 9.5 D. (0.5 inc.)

30.5 – 37.0 D. (0.5 inc.)

Theoretical Standard Power

22.0 D.

Theoretical A-Con. (optical)

118.7

Theoretical ACD (optical)

5.37 mm

Material

PMMA

Filter

UV-Filter

Refractive Index

1.49

Incision

> 7.0 mm

* Other D. on request

IOLS FOR SCLERAL FIXATION
 

Type 90L

Total Diameter

15.0 mm

Optic Diameter

6.5 mm
PositionSulcus

Fixation

We recommend the use of 9-0 double armed Prolene sutures with spatula needles

HapticC-Loop | 10°
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

8.5 – 9.5 D. (0.5 inc.)

Theoretical Standard Power

Sclera sutured= 23.0 D.

Optimized-A-Con. (optical)

Scleral sutured = 118.1

Optimized ACD (optical)

Scleral sutured = 5.02

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

 

Type 66

Total Diameter

13.0 mm

Optic Diameter

6.5 mm
PositionSulcus

Fixation

We recommend the use of 9-0 double armed Prolene sutures with spatula needles

HapticC-Loop | 5°
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

-10.0 – 9.5 D. (0.5 inc.)

30.5 – 35.0 D. (0.5 inc.)

Theoretical Standard Power

22.0 D.

Sclera = 23.0 D.

Theoretical A-Con. (optical)

118.7 | Scleral sutured = 119.6

Theoretical ACD (optical)

5.37 | Scleral sutured = 5.90

Material

PMMA

Filter

UV-Filter

Refractive Index

1.49

Incision> 6.5 mm
MediaSurgery Video
 

Type 81B

Total Diameter

13.5 mm

Optic Diameter

7.0 mm
PositionSulcus

Fixation

We recommend the use of 9-0 double armed Prolene sutures with spatula needles

HapticC-Loop | 10°
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

5.0 – 9.5 D. (0.5 inc.)

30.5 – 35.0 D. (0.5 inc.)

Theoretical Standard Power

22.0 D.

Sclera = 23.0 D.

Theoretical A-Con. (optical)

118.7 | Scleral sutured = 119.6

Theoretical ACD (optical)

5.37 | Scleral sutured = 5.90

Material

PMMA

Filter

UV-Filter

Refractive Index

1.49

Incision> 7.0 mm

* Other D. on request

MICROPHTHALMUS IOL
 

Type 27D

Total Diameter

12.0 mm

Optic Diameter

5.0 mm
PositionCapsular Bag
HapticC-Loop | 6°
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

5.0 – 9.5 D. (0.5 inc.)

30.5 – 75.0 D. (0.5 inc.)

Theoretical Standard Power

22.0 D.

Theoretical A-Con. (optical)

118.7

Theoretical ACD (optical)

5.37 mm

Material

PMMA

Filter

UV-Filter

Refractive Index

1.49

Incision> 5.0 mm
MYOPIA IOLS
 

Type 71A

Total Diameter

14.2 mm

Optic Diameter

6.5 mm
PositionCapsular Bag
HapticJ-Loop | 10°
Standard-Diopter-Range 

-10.0 – 10.0 D. (0.5 inc.)

Theoretical Standard Power

none

Theoretical A-Con. (optical)

118.7

Theoretical ACD (optical)

5.37 mm

Material

PMMA

Filter

UV-Filter

Refractive Index

1.49

Incision> 6.5 mm
 

Type 71B

Total Diameter

14.2 mm

Optic Diameter

6.5 mm
PositionCapsular Bag
HapticC-Loop | 10°
Standard-Diopter-Range 

-12.0 – 10.0 D. (0.5 inc.)

Theoretical Standard Power

none

Theoretical A-Con. (optical)

118.7

Theoretical ACD (optical)

5.37 mm

Material

PMMA

Filter

UV-Filter

Refractive Index

1.49

Incision> 6.5 mm
FEMTO IOLS
 

Masket ND IOL Type 90S // SOON AVAILABLE

Total Diameter

15.0 mm

Optic Diameter

6.0 mm
Body Diameter6.4 mm
ACCC *25.0 mm
Position

Haptic: Capsular Bag
Groove: ACCC *2

Haptic

C-Loop | 0°

Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

8.5 – 9.5 D. (0.5 inc.)

30.5 – 40.0 D. (0.5 inc.)

Theoretical Standard Power

23.0 D.

Theoretical A-Con. (optical)

118.05

Theoretical ACD (optical)

4.97

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Recommended Caliper Ring*3 for ACCC *2

Type 5

FeaturePrevent Negative Dysphotopsia
Security AdviceDue to the possibility of Iris capture it is recommended to keep the Iris in miosis for three days!
ArticlesSolving the Problem of Negative Dysphotopsia - Cataract & Refractive Surgery Today, May 2014
 

Type 89A

Indication

Adults/Pediatrics

Total Diameter

7.5 mm
Optic Diamter5.0 mm
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

8.5 – 9.5 D. (0.5 inc.)

30.5 – 35.0 D. (0.5 inc.)

Theoretical Standard Power

23.0 D.

Theoretical A-Con. (optical)

118.2

Theoretical ACD (optical)

5.08 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Injector (recommendation)

Up to +23.0 diopters 
Medicel ACCUJECTTM 2.2-BL (LP604535)
Wound assisted injection: 1.9 – 2.2 mm 
Wound injection: 2.2 mm

  

For all diopters 
Medicel ACCUJECTTM 2.6-BL (LP604505)
Wound assisted injection: 2.2 mm 
Wound injection: 2.6 mm 

Recommended

Caliper Ring*3 for ACCC*2

Type 5
Type 4L (PED)

Feature

No PCO in visual field!

Note

Surgeons must partake in prerequiste course before implantation!
More information

Security AdviceDue to the possibility of Iris capture it is recommended to keep the Iris in miosis for three days!
MediaInfo Bag-In-The-Lens
Surgery Videos
 

Type 89A TORIC

Indication

Adults/Pediatrics

Total Diameter

7.5 mm
Optic Diamter5.0 mm
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

8.5 – 9.5 D. (0.5 inc.)

Theoretical Standard Power

23.0 D.

Cylindrical Power

0.5 – 8.0 D. (0.5 inc.)

Theoretical A-Con. (optical)

118.2

Theoretical ACD (optical)

5.08 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Injector (recommendation)

Up to +23.0 diopters 
Medicel ACCUJECTTM 2.2-BL (LP604535)
Wound assisted injection: 1.9 – 2.2 mm 
Wound injection: 2.2 mm

  

For all diopters 
Medicel ACCUJECTTM 2.6-BL (LP604505)
Wound assisted injection: 2.2 mm 
Wound injection: 2.6 mm 

Recommended

Caliper Ring*3 for ACCC*2

Type 5
Type 4L (PED)

Feature

No PCO in visual field!

Note

Surgeons must partake in prerequiste course before implantation!
More information

Security AdviceDue to the possibility of Iris capture it is recommended to keep the Iris in miosis for three days!
MediaInfo Bag-In-The-Lens
Surgery Videos
Toric Order Form
 

Type 89D

Indication

For small eyes (< 18.0 mm) and/or
small white to white < 10.0 mm.

Total Diameter

6.5 mm
Optic Diamter4.5 mm
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

8.5 – 9.5 D. (0.5 inc.)

30.5 – 35.0 D. (0.5 inc.)

Theoretical Standard Power

23.0 D.

Theoretical A-Con. (optical)

118.2

Theoretical ACD (optical)

5.08 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Injector (recommendation)

Up to +23.0 diopters 
Medicel ACCUJECTTM 2.2-BL (LP604535)
Wound assisted injection: 1.9 – 2.2 mm 
Wound injection: 2.2 mm

  

For all diopters 
Medicel ACCUJECTTM 2.6-BL (LP604505)
Wound assisted injection: 2.2 mm 
Wound injection: 2.6 mm 

Recommended

Caliper Ring*3 for ACCC*2

Type 4L

Feature

No PCO in visual field!

Note

Surgeons must partake in prerequiste course before implantation!
More information

Security AdviceDue to the possibility of Iris capture it is recommended to keep the Iris in miosis for three days!
MediaInfo Bag-In-The-Lens
Surgery Videos
 

Type 89F

Indication

Combined cataract and vitrectomy procedures or in eyes with large pupils.

Total Diameter

8.5/7.5 mm
Optic Diamter5.0 mm
Standard-Diopter-Range 

10.0 – 30.0 D. (0.5 inc.)

On-Request-Range*

8.5 – 9.5 D. (0.5 inc.)

Theoretical Standard Power

23.0 D.

Theoretical A-Con. (optical)

118.2

Theoretical ACD (optical)

5.08 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Injector (recommendation)

Up to +23.0 diopters 
Medicel ACCUJECTTM 2.2-BL (LP604535)
Wound assisted injection: 1.9 – 2.2 mm 
Wound injection: 2.2 mm

  

For all diopters 
Medicel ACCUJECTTM 2.6-BL (LP604505)
Wound assisted injection: 2.2 mm 
Wound injection: 2.6 mm 

Recommended

Caliper Ring*3 for ACCC*2

Type 5

Feature

No PCO in visual field!

Note

Surgeons must partake in prerequiste course before implantation!
More information

Security AdviceDue to the possibility of Iris capture it is recommended to keep the Iris in miosis for three days!
MediaInfo Bag-In-The-Lens
Surgery Videos

* Other D. on request 
*2 Anterior Continuous Curvolinear Capsulorhexis 
*3 Gauge for Capsulorhexis