Intraocular Lenses

HYDROPHILIC IOLS
 

Type 92S

Total Diameter

15.0 mm

Optic Diameter

6.0 mm
Position

Capsular Bag

Haptic

C-Loop | 10°

Standard Diopter Range 

10.0 – 30.0 D (0.5 inc.)

On Request Diopter Range

8.5 – 9.5 D (0.5 inc.)

30.5 – 40.0 D (0.5 inc.)

Theoretical Standard Diopter

23.0 D

Theoretical A-Con. (optical)

119.7 | Scleral sutured = 120.6

Theoretical ACD (optical)

5.96 mm | Scleral sutured = 6.48 mm

Haigis

a0 = 1.40 | a1 = 0.40 | a2 = 0.10

SRK/T | SRKII

119.1 | 119.6

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

MediaSurgery Video
Instruction For UseeIFU-System
 

Type 46G UV PLUS

Total Diameter

15.0 mm

Optic Diameter

6.0 mm
Position

Capsular Bag

Haptic

C-Loop | 10°

Standard Diopter Range 

10.0 – 30.0 D (0.5 inc.)

On Request Diopter Range

8.5 – 9.5 D (0.5 inc.)

30.5 – 40.0 D (0.5 inc.)

Theoretical Standard Diopter

23.0 D

Theoretical A-Con. (optical)

119.7 | Scleral sutured = 120.6

Theoretical ACD (optical)

5.96 mm | Scleral sutured = 6.48 mm

Haigis

a0 = 1.40 | a1 = 0.40 | a2 = 0.10

SRK/T | SRKII

119.1 | 119.6

Material

Hydrophilic Acrylic

Water Content

28.0 %

Refractive Index

1.46

Instruction For UseeIFU-System
 

Type 90L

Total Diameter

15.0 mm

Optic Diameter

6.5 mm
PositionCapsular Bag
HapticC-Loop | 10°
Standard Diopter Range 

10.0 – 30.0 D (0.5 inc.)

On Request Diopter-Range

8.5 – 9.5 D (0.5 inc.)

Theoretical Standard Diopter

22.0 D | Scleral sutured= 23.0 D

Theoretical A-Con. (optical)119.7 | Scleral sutured = 120.6
Theoretical ACD (optical)5.96 mm | Scleral sutured = 6.48 mm
Optimized-A-Con. (optical)

Scleral sutured = 118.1

Optimized ACD (optical)

Scleral sutured = 5.02 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Instruction For UseeIFU-System
 

Type 92G

Total Diameter

15.0 mm

Optic Diameter

6.5 mm
Position

Capsular Bag

Haptic

C-Loop | 10°

Standard Diopter Range 

10.0 – 30.0 D (0.5 inc.)

On Request Diopter Range

8.5 – 9.5 D (0.5 inc.)

Theoretical Standard Diopter

22.0 D

Theoretical A-Con. (optical)

119.7 | Scleral sutured = 120.6

Theoretical ACD (optical)

5.96 mm | Scleral sutured = 6.48 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Instruction For UseeIFU-System
 

Type 92B

Total Diameter

15.0 mm

Optic Diameter

7.0 mm
Position

Capsular Bag

Haptic

C-Loop | 10°

Standard Diopter Range 

10.0 – 30.0 D (0.5 inc.)

On Request Diopter Range

8.5 – 9.5 D (0.5 inc.)

Theoretical Standard Diopter

21.0 D

Theoretical A-Con. (optical)

119.7 | Scleral sutured = 120.6

Theoretical ACD (optical)

5.96 mm | Scleral sutured = 6.48 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Note

Cannot be implanted with an

injector due to its optic size.

Instruction For UseeIFU-System
 

Type 92C

Total Diameter

10.5 mm

Optic Diameter

6.0 mm
Position

Capsular Bag

Haptic

4-Loop | 10°

Standard Diopter Range 

15.0 – 30.0 D (0.5 inc.)

On Request Diopter Range

8.5 – 14.5 D (0.5 inc.)

30.5 – 35.0 D (0.5 inc.)

Theoretical Standard Diopter

22.0 D

Theoretical A-Con. (optical)

119.1

Theoretical ACD (optical)

5.61 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Instruction For UseeIFU-System
 

Type 97B


Total Diameter

11.0 mm

10.75 mm10.5 mm

Optic Diameter

6.5 mm6.25 mm / 5.75 mm6.0 mm / 5.5 mm
Opticconvexo-concavebiconvexbiconvex
Position

Capsular Bag

Capsular BagCapsular Bag
Haptic

4-Loop | 0°

4-Loop | 0°4-Loop | 0°
Diopter Range 

-5.0  –  4.5 D

(0.5 inc.)

5.0  –  14.5 D

(0.5 inc.)

15.0  –  35.0 D

(0.5 inc.)

Theoretical Standard Diopter

22.0 D

22.0 D22.0 D
Theoretical A-Con. (optical)

118.8

118.8118.8
Theoretical ACD (optical)

5.43 mm

5.43 mm5.43 mm
Optimized A-Con. SRKT (optical)*3118.8118.8118.4
Material

Hydrophilic Acrylic

Hydrophilic AcrylicHydrophilic Acrylic
Water Content

28.0 %

28.0 %28.0 %
Filter

UV-Filter

UV-FilterUV-Filter
Refractive Index

1.46

1.461.46
Instruction For UseeIFU-SystemeIFU-SystemeIFU-System
 

Type 89A

Indication

Adults/Pediatrics

Total Diameter

7.5 mm
Optic Diamter5.0 mm
Standard Diopter Range 

10.0 – 30.0 D (0.5 inc.)

On Request Diopter-Range

8.5 – 9.5 D (0.5 inc.)

30.5 – 35.0 D (0.5 inc.)

Theoretical Standard Diopter

23.0 D

Theoretical A-Con. (optical)

118.2

Theoretical ACD (optical)

5.08 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Recommended

Caliper Ring*2 for ACCC*1

Type 5
Type 4L (PED)

Note

Surgeons must partake in prerequiste course before implantation!

Security AdviceDue to the possibility of iris capture it is recommended to keep the pupil in myosis in the early postoperative period.
MediaSurgery Videos
Instruction For UseeIFU-System
 

Type 89D

Indication

For short eyes (< 18.0 mm) and/or
small white to white < 10.0 mm

Total Diameter

6.5 mm
Optic Diamter4.5 mm
Standard Diopter Range 

10.0 – 30.0 D (0.5 inc.)

On Request Diopter Range

8.5 – 9.5 D (0.5 inc.)

30.5 – 35.0 D (0.5 inc.)

Theoretical Standard Diopter

23.0 D

Theoretical A-Con. (optical)

118.2

Theoretical ACD (optical)

5.08 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Recommended

Caliper Ring*2 for ACCC*1

Type 4L

Note

Surgeons must partake in prerequiste course before implantation!

Security AdviceDue to the possibility of iris capture it is recommended to keep the pupil in myosis in the early postoperative period.
MediaSurgery Videos
Instruction For UseeIFU-System
 

Type 89F

Indication

Combined cataract and vitrectomy procedures or in eyes with large pupils

Total Diameter

8.5/7.5 mm
Optic Diamter5.0 mm
Standard Diopter Range 

10.0 – 30.0 D (0.5 inc.)

On Request Diopter Range

8.5 – 9.5 D (0.5 inc.)

Theoretical Standard Diopter

23.0 D

Theoretical A-Con. (optical)

118.2

Theoretical ACD (optical)

5.08 mm

Material

Hydrophilic Acrylic

Water Content

28.0 %

Filter

UV-Filter

Refractive Index

1.46

Recommended

Caliper Ring*2 for ACCC*1

Type 5

Note

Surgeons must partake in prerequiste course before implantation!

Security AdviceDue to the possibility of iris capture it is recommended to keep the pupil in myosis in the early postoperative period.
MediaSurgery Videos
Instruction For UseeIFU-System

*1 Anterior Continuous Curvolinear Capsulorhexis 
*2 Gauge for Capsulorhexis
*3 by B. Golenvaux, MD