Aniridia Rings TYPE 50C
| Size (compressed): | 10,0 mm |
|---|---|
| Total Diameter: | 10,61 |
| Diaphragm: | Covers up to 12 cl. hours / 360° |
| Inner Diameter: | 6,0 mm |
| Incision: | > 2,0 mm |
| Diopter Range: | None |
| Material: | PEMA Black CQ |
Aniridia Rings TYPE 50E
| Size (compressed): | 10,0 mm |
|---|---|
| Total Diameter: | 10,61 |
| Diaphragm: | Cover up to 12 cl.hours / 360° |
| Inner Diameter: | 3,5 mm |
| Incision: | > 3,25 mm |
| Diopter Range: | None |
| Material: | PEMA Black CQ |
Aniridia Rings TYPE 50F
| Size (compressed): | 10,0 mm |
|---|---|
| Total Diameter: | 10,19 |
| Diaphragm: | Cover up to 12 cl. hours / 360° |
| Inner Diameter: | 4,0 mm |
| Incision: | > 3,0 mm |
| Diopter Range: | None |
| Material: | PEMA Black CQ |
Aniridia Rings TYPE 96C
| Size (compressed): | 12,5 mm |
|---|---|
| Total Diameter: | 13 |
| Diaphragm: | Cover up to 12 cl. hours / 360° |
| Inner Diameter: | 4,0 mm |
| Incision: | > 4,5 mm |
| Diopter Range: | None |
| Material: | PEMA Black CQ |
| Features: | Sulcus Ring |
Partial Aniridia Rings
Partial Aniridia Rings TYPE 94G
| Size (compressed): | 10,0 mm |
|---|---|
| Total Diameter: | 11,46 |
| Diaphragm: | Cover up to 3 cl. hours / 90° |
| Inner Diameter: | 6,5 mm |
| Incision: | > 1,75 mm |
| Diopter Range: | None |
| Material: | PEMA Black CQ |
Partial Aniridia Rings TYPE 96E
| Size (compressed): | 11,0 mm |
|---|---|
| Total Diameter: | 13 |
| Diaphragm: | Cover up to 3 cl. hours / 90° |
| Inner Diameter: | 5,5 mm |
| Incision: | > 3,0 mm |
| Diopter Range: | None |
| Material: | PEMA Black CQ |
Partial Aniridia Rings TYPE 96F
| Size (compressed): | 11,0 mm |
|---|---|
| Total Diameter: | 12,9 |
| Diaphragm: | Cover up to 3 cl. hours / 90° |
| Inner Diameter: | 4,0 mm |
| Incision: | > 3,5 mm |
| Diopter Range: | None |
| Material: | PEMA Black CQ |
Partial Aniridia Rings TYPE 96G
| Size (compressed): | 11,0 mm |
|---|---|
| Total Diameter: | 12,26 |
| Diaphragm: | Cover up to 3 cl. hours / 90° |
| Inner Diameter: | 4.0 mm |
| Incision: | > 3,5 mm |
| Diopter Range: | None |
| Material: | PEMA Black CQ |
Aniridia Implants
Aniridia Implants TYPE 67B
| Total Diameter: | 12,5 |
|---|---|
| Body: | 10 |
| Optic Diameter: | 3 |
| Diaphragm: | 3,0 - 10,0 mm |
| Incision: | > 10,0 mm |
| Haptic Angulation: | 0° |
| Diopter Range: | 10 - 30 |
| Etd. Standard Power: | 22 |
| Etd. A-Constant AB*¹: | 118,1 |
| Etd. A-Constant OB*²: | 118,7 |
| ACD AB*¹: | 5,02 |
| ACD OB*²: | 5,37 |
| Material (haptic): | PEMA Black CQ |
| Material (Optic): | PMMA CQ UV |
AB*¹ = Acoustic biometry | OB*² = Optical biometry
All numbers listed within the catalog are presented as guidelines only. We recommend you develop your own A-constants based on your experience.
Aniridia Implants TYPE 67F
| Total Diameter: | 13,5 |
|---|---|
| Body: | 10 |
| Optic Diameter: | 5 |
| Diaphragm: | 5,0 - 10,0 mm |
| Incision: | > 10,0 mm |
| Haptic Angulation: | 0° |
| Diopter Range: | 10 - 30 |
| Etd. Standard Power: | 22 |
| Etd. A-Constant AB*¹: | 118,1 |
| Etd. A-Constant OB*²: | 118,7 |
| ACD AB*¹: | 5,02 |
| ACD OB*²: | 5,37 |
| Material (haptic): | PEMA Black CQ |
| Material (Optic): | PMMA CQ UV |
| Features: | For myopic eyes/ Also available without optic |
AB*¹ = Acoustic biometry | OB*² = Optical biometry
All numbers listed within the catalog are presented as guidelines only. We recommend you develop your own A-constants based on your experience.
Aniridia Implants TYPE 67G
| Total Diameter: | 12,5 |
|---|---|
| Body: | 10 |
| Optic Diameter: | 5 |
| Diaphragm: | 3,0 - 10,0 mm |
| Incision: | > 10,0 mm |
| Haptic Angulation: | 0° |
| Diopter Range: | 10 - 30 |
| Etd. Standard Power: | 22 |
| Etd. A-Constant AB*¹: | 118,1 |
| Etd. A-Constant OB*²: | 118,7 |
| ACD AB*¹: | 5,02 |
| ACD OB*²: | 5,37 |
| Material (haptic): | PEMA Black CQ |
| Material (Optic): | PMMA CQ UV |
| Features: | Also available without optic |
AB*¹ = Acoustic biometry | OB*² = Optical biometry
All numbers listed within the catalog are presented as guidelines only. We recommend you develop your own A-constants based on your experience.
Aniridia Implants TYPE 67L
| Total Diameter: | 13,5 |
|---|---|
| Body: | 10 |
| Optic Diameter: | 5 |
| Diaphragm: | 5,0 - 10,0 mm |
| Incision: | > 10,0 mm |
| Haptic Angulation: | 0° |
| Diopter Range: | 10 - 30 |
| Etd. Standard Power: | 22 |
| Etd. A-Constant AB*¹: | 118,1 |
| Etd. A-Constant OB*²: | 118,7 |
| ACD AB*¹: | 5,02 |
| ACD OB*²: | 5,37 |
| Material (haptic): | PEMA Black CQ |
| Material (Optic): | PMMA CQ UV |
| Features: | IOL with opening in the diaphragm (1,5-3,0 mm) for the injection of vitreous body substitution/ Also available without optic<br/> |
AB*¹ = Acoustic biometry | OB*² = Optical biometry
All numbers listed within the catalog are presented as guidelines only. We recommend you develop your own A-constants based on your experience.
Aniridia Implants TYPE 68
| Total Diameter: | 12,5 |
|---|---|
| Body: | 10 |
| Optic Diameter: | 4,5 |
| Diaphragm: | 4,5 - 10, 0 mm |
| Incision: | > 10,0 mm |
| Haptic Angulation: | 0° |
| Diopter Range: | 10 - 30 |
| Etd. Standard Power: | 22 |
| Etd. A-Constant AB*¹: | 118,1 |
| Etd. A-Constant OB*²: | 118,7 |
| ACD AB*¹: | 5,02 |
| ACD OB*²: | 5,37 |
| Material (haptic): | PEMA Black CQ |
| Material (Optic): | PMMA CQ UV |
AB*¹ = Acoustic biometry | OB*² = Optical biometry
All numbers listed within the catalog are presented as guidelines only. We recommend you develop your own A-constants based on your experience.
Aniridia Implants TYPE 94A
| Total Diameter: | 13 |
|---|---|
| Body: | 10 |
| Optic Diameter: | 6,5 |
| Diaphragm: | 6,5 - 10,0 mm |
| Incision: | > 10,0 mm |
| Diopter Range: | None |
| Etd. Standard Power: | None |
| Material (haptic): | PEMA Black CQ |
| Features: | Only available without optic |
Partial Aniridia Implants
Partial Aniridia Implants TYPE 67
| Total Diameter: | 12,5 |
|---|---|
| Body: | 10 |
| Optic Diameter: | 3,5 |
| Diaphragm: | 3,0 - 7/10,0 mm |
| Incision: | > 7,0 mm |
| Haptic Angulation: | 10° |
| Diopter Range: | 10 - 30 |
| Etd. Standard Power: | 22 |
| Etd. A-Constant AB*¹: | 118,1 |
| Etd. A-Constant OB*²: | 118,7 |
| ACD AB*¹: | 5,02 |
| ACD OB*²: | 5,37 |
| Material (haptic): | PEMA Black CQ |
| Material (Optic): | PMMA CQ UV |
| Features: | Also available without optic |
AB*¹ = Acoustic biometry | OB*² = Optical biometry
All numbers listed within the catalog are presented as guidelines only. We recommend you develop your own A-constants based on your experience.
Partial Aniridia Implants TYPE 67A
| Total Diameter: | 14 |
|---|---|
| Body: | 10 |
| Optic Diameter: | 3,5 |
| Diaphragm: | 3,5 - 7/10,0 mm |
| Incision: | > 7,0 mm |
| Haptic Angulation: | 10° |
| Diopter Range: | 10 - 30 |
| Etd. Standard Power: | 22 |
| Etd. A-Constant AB*¹: | 118,1 |
| Etd. A-Constant OB*²: | 118,7 |
| ACD AB*¹: | 5,02 |
| ACD OB*²: | 5,37 |
| Material (haptic): | PEMA Black CQ |
| Material (Optic): | PMMA CQ UV |
| Features: | For myopic eyes/Also available without optic |
AB*¹ = Acoustic biometry | OB*² = Optical biometry
All numbers listed within the catalog are presented as guidelines only. We recommend you develop your own A-constants based on your experience.
Partial Aniridia Implants TYPE 67D
| Total Diameter: | 13,5 |
|---|---|
| Body: | 10 |
| Optic Diameter: | 3,5 |
| Diaphragm: | 3,5 - 7/10,0 mm |
| Incision: | > 7,0 mm |
| Haptic Angulation: | 5° |
| Diopter Range: | 10 - 30 |
| Etd. Standard Power: | 23 |
| Etd. A-Constant AB*¹: | 119 |
| Etd. A-Constant OB*²: | 119,6 |
| ACD AB*¹: | 5,55 |
| ACD OB*²: | 5,9 |
| Material (haptic): | PEMA Black CQ |
| Material (Optic): | PMMA CQ UV |
| Features: | Option for scleral fixation |
AB*¹ = Acoustic biometry | OB*² = Optical biometry
All numbers listed within the catalog are presented as guidelines only. We recommend you develop your own A-constants based on your experience.
Partial Aniridia Implants TYPE 67E
| Total Diameter: | 13,5 |
|---|---|
| Body: | 8 |
| Optic Diameter: | 4 |
| Diaphragm: | 4,0 - 8,0 mm |
| Incision: | > 8,0 mm |
| Haptic Angulation: | 5° |
| Diopter Range: | 10 - 30 |
| Etd. Standard Power: | 23 |
| Etd. A-Constant AB*¹: | 119 |
| Etd. A-Constant OB*²: | 119,6 |
| ACD AB*¹: | 5,55 |
| ACD OB*²: | 5,9 |
| Material (haptic): | PEMA Black CQ |
| Material (Optic): | PMMA CQ UV |
| Features: | For patients with a partial iris hem left and the option for scleral fixation |
AB*¹ = Acoustic biometry | OB*² = Optical biometry
All numbers listed within the catalog are presented as guidelines only. We recommend you develop your own A-constants based on your experience.
Partial Aniridia Implants TYPE 67S
| Total Diameter: | 13,5 |
|---|---|
| Body: | 8 |
| Optic Diameter: | 5 |
| Diaphragm: | 5,0 - 8,0 mm |
| Incision: | > 8,0 mm |
| Haptic Angulation: | 10° |
| Diopter Range: | 10 - 30 |
| Etd. Standard Power: | 22 |
| Etd. A-Constant AB*¹: | 118,1 |
| Etd. A-Constant OB*²: | 118,7 |
| ACD AB*¹: | 5,02 |
| ACD OB*²: | 5,37 |
| Material (haptic): | PEMA Black CQ |
| Material (Optic): | PMMA CQ UV |
| Features: | For patients with a partial iris hem left/ Also available without optic |
AB*¹ = Acoustic biometry | OB*² = Optical biometry
All numbers listed within the catalog are presented as guidelines only. We recommend you develop your own A-constants based on your experience.
Partial Aniridia Implants TYPE 68C
| Total Diameter: | 14 |
|---|---|
| Body: | 10 |
| Optic Diameter: | 3,5 |
| Diaphragm: | 3,0 - 7/10,0 mm |
| Incision: | > 7,0 mm |
| Haptic Angulation: | 10° |
| Diopter Range: | 10 - 30 |
| Etd. Standard Power: | 22 |
| Etd. A-Constant AB*¹: | 118,1 |
| Etd. A-Constant OB*²: | 118,7 |
| ACD AB*¹: | 5,02 |
| ACD OB*²: | 5,37 |
| Material (haptic): | PEMA Black CQ |
| Material (Optic): | PMMA CQ UV |
| Features: | Option for scleral fixation |
AB*¹ = Acoustic biometry | OB*² = Optical biometry
All numbers listed within the catalog are presented as guidelines only. We recommend you develop your own A-constants based on your experience.
Partial Aniridia Implants TYPE 94
| Total Diameter: | 13,5 |
|---|---|
| Body: | 8 |
| Optic Diameter: | 4 |
| Diaphragm: | 4,0 - 8,0 mm |
| Incision: | > 8.0 mm |
| Haptic Angulation: | 10° |
| Diopter Range: | 10 - 30 |
| Etd. Standard Power: | 22 |
| Etd. A-Constant AB*¹: | 118,1 |
| Etd. A-Constant OB*²: | 118,7 |
| ACD AB*¹: | 5,02 |
| ACD OB*²: | 5,37 |
| Material (haptic): | PEMA Black CQ |
| Material (Optic): | PMMA CQ UV |
| Features: | For patients with a partial iris hem left/ Also available without optic |
AB*¹ = Acoustic biometry | OB*² = Optical biometry
All numbers listed within the catalog are presented as guidelines only. We recommend you develop your own A-constants based on your experience.
Partial Aniridia Implants TYPE 94C
| Total Diameter: | 13,5 |
|---|---|
| Body: | 8 |
| Optic Diameter: | 4 |
| Diaphragm: | 4,0 - 8,0 mm |
| Incision: | > 8,0 mm |
| Haptic Angulation: | 10° |
| Diopter Range: | 10 - 30 |
| Etd. Standard Power: | 22 |
| Etd. A-Constant AB*¹: | 118,1 |
| Etd. A-Constant OB*²: | 118,7 |
| ACD AB*¹: | 5,02 |
| ACD OB*²: | 5,37 |
| Material (haptic): | PEMA Black CQ |
| Material (Optic): | PMMA CQ UV |
| Features: | For patients with a partial iris hem left and the option for scleral fixation |
AB*¹ = Acoustic biometry | OB*² = Optical biometry